Water curtain sprinkler ZSTMB/ZSTMC
ZSTMB/ZSTMC
Retail price
Market price
Weight
kg
Stock
隐藏域元素占位
Key words:
Water curtain sprinkler
- Product Description
-
- Commodity name: Water curtain sprinkler ZSTMB/ZSTMC
- Commodity ID: ZSTMB/ZSTMC
1. model preparation:
1. Structure code:
Code A: indicates that the inclination angle of the water curtain is 0 °.
Code B: indicates that the inclination angle of the water curtain is 90 ° and there is only one water outlet.
Code C: indicates that the inclination angle of the water curtain is 90 ° and there are two outlets.
Code D: indicates that the inclination angle of the water curtain is not 0 ° or 90 °.
2. Usage feature code:
Code G: It is only applicable to water curtain nozzle for fire separation.
Code L: It is only applicable to water curtain nozzle for protective cooling.
Code T: universal water curtain nozzle applicable to both fire separation and protective cooling.
Example 1.ZSTM A- T40/120 represents a type A, general-purpose water curtain nozzle with a nominal flow coefficient of 40 and a water curtain spread angle of 120.
2.ZSTM D-L60/150 represents a water curtain nozzle with D type, protective cooling, nominal flow coefficient of 60 and water curtain spread angle of 150.
2. executive standard: GB5135.13-2006 "automatic sprinkler system part 13: water curtain nozzle"
3. technical parameters:
Model specifications
Flow characteristic coefficient K
Inclination of water curtain
Water Curtain Angle
Structure form
Interface thread
Nominal diameter
Minimum working pressure (MPa)
ZSTM B-T3/120
3
90 degrees
120°
Single-gap type
R1/2
DN15
0.10
ZSTM B-T5/120
5
90 degrees
120°
Single-gap type
R1/2
DN15
0.10
ZSTM B-T8/120
8
90 degrees
120°
Single-gap type
R1/2
DN15
0.10
ZSTM B-T15/120
15
90 degrees
120°
Single-gap type
R1/2
DN15
0.10
ZSTM B-T20/120
20
90 degrees
120°
Single-gap type
R1/2
DN15
0.10
ZSTM B-T30/120
30
90 degrees
120°
Single-gap type
R3/4
DN20
0.10
ZSTM B-T35/120
35
90 degrees
120°
Single-gap type
R3/4
DN20
0.10
ZSTM B-T40/120
40
90 degrees
120°
Single-gap type
R3/4
DN20
0.10
ZSTM B-T52/120
52
90 degrees
120°
Single-gap type
R3/4
DN20
0.10
4. applicable places: it is mainly installed in the stage entrance, doors and windows, holes and cornices to stop fire and cut off fire sources. it can also be used in conjunction with fire doors, fire shutter and fire curtain to increase its fire resistance through cooling, and can also be used as a separate fire compartment instead of fire separation facilities.
1. model preparation:
1. Structure code:
Code A: indicates that the inclination angle of the water curtain is 0 °.
Code B: indicates that the inclination angle of the water curtain is 90 ° and there is only one water outlet.
Code C: indicates that the inclination angle of the water curtain is 90 ° and there are two outlets.
Code D: indicates that the inclination angle of the water curtain is not 0 ° or 90 °.
2. Usage feature code:
Code G: It is only applicable to water curtain nozzle for fire separation.
Code L: It is only applicable to water curtain nozzle for protective cooling.
Code T: universal water curtain nozzle applicable to both fire separation and protective cooling.
Example 1.ZSTM A- T40/120 represents a type A, general-purpose water curtain nozzle with a nominal flow coefficient of 40 and a water curtain spread angle of 120.
2.ZSTM D-L60/150 represents a water curtain nozzle with D type, protective cooling, nominal flow coefficient of 60 and water curtain spread angle of 150.
2. executive standard: GB5135.13-2006 "automatic sprinkler system part 13: water curtain nozzle"
3. technical parameters:
Model specifications |
Flow characteristic coefficient K |
Inclination of water curtain |
Water Curtain Angle |
Structure form |
Interface thread |
Nominal diameter |
Minimum working pressure (MPa) |
ZSTM B-T3/120 |
3 |
90 degrees |
120° |
Single-gap type |
R1/2 |
DN15 |
0.10 |
ZSTM B-T5/120 |
5 |
90 degrees |
120° |
Single-gap type |
R1/2 |
DN15 |
0.10 |
ZSTM B-T8/120 |
8 |
90 degrees |
120° |
Single-gap type |
R1/2 |
DN15 |
0.10 |
ZSTM B-T15/120 |
15 |
90 degrees |
120° |
Single-gap type |
R1/2 |
DN15 |
0.10 |
ZSTM B-T20/120 |
20 |
90 degrees |
120° |
Single-gap type |
R1/2 |
DN15 |
0.10 |
ZSTM B-T30/120 |
30 |
90 degrees |
120° |
Single-gap type |
R3/4 |
DN20 |
0.10 |
ZSTM B-T35/120 |
35 |
90 degrees |
120° |
Single-gap type |
R3/4 |
DN20 |
0.10 |
ZSTM B-T40/120 |
40 |
90 degrees |
120° |
Single-gap type |
R3/4 |
DN20 |
0.10 |
ZSTM B-T52/120 |
52 |
90 degrees |
120° |
Single-gap type |
R3/4 |
DN20 |
0.10 |
4. applicable places: it is mainly installed in the stage entrance, doors and windows, holes and cornices to stop fire and cut off fire sources. it can also be used in conjunction with fire doors, fire shutter and fire curtain to increase its fire resistance through cooling, and can also be used as a separate fire compartment instead of fire separation facilities.