Product classification


undefined
+
  • undefined

Click image to enlarge

No.:

ZSTMB/ZSTMC

Water curtain sprinkler ZSTMB/ZSTMC

ZSTMB/ZSTMC

Retail price

Market price


Weight

kg

Quantity
-
+

Stock

隐藏域元素占位

Key words:

Water curtain sprinkler

  • Product Description
    • Commodity name: Water curtain sprinkler ZSTMB/ZSTMC
    • Commodity ID: ZSTMB/ZSTMC

    1. model preparation:

    1. Structure code:

    Code A: indicates that the inclination angle of the water curtain is 0 °.

    Code B: indicates that the inclination angle of the water curtain is 90 ° and there is only one water outlet.

    Code C: indicates that the inclination angle of the water curtain is 90 ° and there are two outlets.

    Code D: indicates that the inclination angle of the water curtain is not 0 ° or 90 °.

    2. Usage feature code:

    Code G: It is only applicable to water curtain nozzle for fire separation.

    Code L: It is only applicable to water curtain nozzle for protective cooling.

    Code T: universal water curtain nozzle applicable to both fire separation and protective cooling.

     

    Example 1.ZSTM A- T40/120 represents a type A, general-purpose water curtain nozzle with a nominal flow coefficient of 40 and a water curtain spread angle of 120.

    2.ZSTM D-L60/150 represents a water curtain nozzle with D type, protective cooling, nominal flow coefficient of 60 and water curtain spread angle of 150.

     

    2. executive standard: GB5135.13-2006 "automatic sprinkler system part 13: water curtain nozzle"

    3. technical parameters:

    Model specifications

    Flow characteristic coefficient K

    Inclination of water curtain

    Water Curtain Angle

    Structure form

    Interface thread

    Nominal diameter

    Minimum working pressure (MPa)

    ZSTM B-T3/120

    3

    90 degrees

    120°

    Single-gap type

    R1/2

    DN15

    0.10

    ZSTM B-T5/120

    5

    90 degrees

    120°

    Single-gap type

    R1/2

    DN15

    0.10

    ZSTM B-T8/120

    8

    90 degrees

    120°

    Single-gap type

    R1/2

    DN15

    0.10

    ZSTM B-T15/120

    15

    90 degrees

    120°

    Single-gap type

    R1/2

    DN15

    0.10

    ZSTM B-T20/120

    20

    90 degrees

    120°

    Single-gap type

    R1/2

    DN15

    0.10

    ZSTM B-T30/120

    30

    90 degrees

    120°

    Single-gap type

    R3/4

    DN20

    0.10

    ZSTM B-T35/120

    35

    90 degrees

    120°

    Single-gap type

    R3/4

    DN20

    0.10

    ZSTM B-T40/120

    40

    90 degrees

    120°

    Single-gap type

    R3/4

    DN20

    0.10

    ZSTM B-T52/120

    52

    90 degrees

    120°

    Single-gap type

    R3/4

    DN20

    0.10

     

    4. applicable places: it is mainly installed in the stage entrance, doors and windows, holes and cornices to stop fire and cut off fire sources. it can also be used in conjunction with fire doors, fire shutter and fire curtain to increase its fire resistance through cooling, and can also be used as a separate fire compartment instead of fire separation facilities.

1. model preparation:

1. Structure code:

Code A: indicates that the inclination angle of the water curtain is 0 °.

Code B: indicates that the inclination angle of the water curtain is 90 ° and there is only one water outlet.

Code C: indicates that the inclination angle of the water curtain is 90 ° and there are two outlets.

Code D: indicates that the inclination angle of the water curtain is not 0 ° or 90 °.

2. Usage feature code:

Code G: It is only applicable to water curtain nozzle for fire separation.

Code L: It is only applicable to water curtain nozzle for protective cooling.

Code T: universal water curtain nozzle applicable to both fire separation and protective cooling.

 

Example 1.ZSTM A- T40/120 represents a type A, general-purpose water curtain nozzle with a nominal flow coefficient of 40 and a water curtain spread angle of 120.

2.ZSTM D-L60/150 represents a water curtain nozzle with D type, protective cooling, nominal flow coefficient of 60 and water curtain spread angle of 150.

 

2. executive standard: GB5135.13-2006 "automatic sprinkler system part 13: water curtain nozzle"

3. technical parameters:

Model specifications

Flow characteristic coefficient K

Inclination of water curtain

Water Curtain Angle

Structure form

Interface thread

Nominal diameter

Minimum working pressure (MPa)

ZSTM B-T3/120

3

90 degrees

120°

Single-gap type

R1/2

DN15

0.10

ZSTM B-T5/120

5

90 degrees

120°

Single-gap type

R1/2

DN15

0.10

ZSTM B-T8/120

8

90 degrees

120°

Single-gap type

R1/2

DN15

0.10

ZSTM B-T15/120

15

90 degrees

120°

Single-gap type

R1/2

DN15

0.10

ZSTM B-T20/120

20

90 degrees

120°

Single-gap type

R1/2

DN15

0.10

ZSTM B-T30/120

30

90 degrees

120°

Single-gap type

R3/4

DN20

0.10

ZSTM B-T35/120

35

90 degrees

120°

Single-gap type

R3/4

DN20

0.10

ZSTM B-T40/120

40

90 degrees

120°

Single-gap type

R3/4

DN20

0.10

ZSTM B-T52/120

52

90 degrees

120°

Single-gap type

R3/4

DN20

0.10

 

4. applicable places: it is mainly installed in the stage entrance, doors and windows, holes and cornices to stop fire and cut off fire sources. it can also be used in conjunction with fire doors, fire shutter and fire curtain to increase its fire resistance through cooling, and can also be used as a separate fire compartment instead of fire separation facilities.

水幕喷头.jpg