Product classification


undefined
+
  • undefined

Click image to enlarge

No.:

SQD150-2.5A

Multi-use fire pump adapter SQD150-2.5A

SQD150-2.5A

Retail price

Market price


Weight

kg

Quantity
-
+

Stock

隐藏域元素占位

Key words:

Multi-use fire pump adapter

  • Product Description
    • Commodity name: Multi-use fire pump adapter SQD150-2.5A
    • Commodity ID: SQD150-2.5A

    1. model preparation:

     

     

    Example: SQS100-1.6 indicates a ground fire pump adapter with nominal diameter of 100mm, nominal pressure of 1.6MPa and flange connection.

    2. executive standard: GB3446-2013 "fire pump adapter"

    3. parameters:

    Product Name

    Model specifications

    Nominal diameter mm

    Nominal pressure MPa

    Water inlet interface specification

    Diameter of outlet mm

    Applicable media

    Above ground

    Fire pump adapter

    SQS100-1.6

    100

    1.6

    KWS 65 × 2

    100

    Water, foam mixture

    SQS150-1.6

    150

    KWS 80 × 2

    150

    SQS100-1.6A

    100

    KWS 65 × 2

    100

    SQS150-1.6A

    150

    KWS 80 × 2

    150

    underground type

    Fire pump adapter

    SQA100-1.6

    100

    KWA 65 × 2

    100

    SQA150-1.6

    150

    KWA 80 × 2

    150

    SQA100-1.6A

    100

    KWA 65 × 2

    100

    SQA150-1.6A

    150

    KWA 80 × 2

    150

    wall type

    Fire pump adapter

    SQB100-1.6A

    100

    KWS 65 × 2

    100

    SQB150-1.6A

    150

    KWS 80 × 2

    150

    Multi-use

    Fire pump adapter

    SQD100-1.6

    100

    KWS 65 × 2

    100

    SQD150-1.6

    150

    KWS 80 × 2

    150

    SQD100-1.6A

    100

    KWS 65 × 2

    100

    SQD150-1.6A

    150

    KWS 80 × 2

    150

    Above ground

    Fire pump adapter

    SQS100-2.5

    100

    2.5

    KWS 65 × 2

    100

    SQS150-2.5

    150

    KWS 80 × 2

    150

    underground type

    Fire pump adapter

    SQA100-2.5

    100

    KWA 65 × 2

    100

    SQA150-2.5

    150

    KWA 80 × 2

    150

    Multi-use

    Fire pump adapter

    SQD100-2.5

    100

    KWS 65 × 2

    100

    SQD150-2.5

    150

    KWS 80 × 2

    150

    SQD100-2.5A

    100

    KWA 65 × 2

    100

    SQD150-2.5A

    150

    KWA 80 × 2

    150

     

    4. applicable places: water pump adapter is based on"Code for fire protection design of buildings"Fire fighting facilities for high-rise buildings. Usually within the building.automatic sprinkler systemOr connected to the water supply system of fire fighting equipment such as fire hydrants.

1. model preparation:

 

 

Example: SQS100-1.6 indicates a ground fire pump adapter with nominal diameter of 100mm, nominal pressure of 1.6MPa and flange connection.

2. executive standard: GB3446-2013 "fire pump adapter"

3. parameters:

Product Name

Model specifications

Nominal diameter mm

Nominal pressure MPa

Water inlet interface specification

Diameter of outlet mm

Applicable media

Above ground

Fire pump adapter

SQS100-1.6

100

1.6

KWS 65 × 2

100

Water, foam mixture

SQS150-1.6

150

KWS 80 × 2

150

SQS100-1.6A

100

KWS 65 × 2

100

SQS150-1.6A

150

KWS 80 × 2

150

underground type

Fire pump adapter

SQA100-1.6

100

KWA 65 × 2

100

SQA150-1.6

150

KWA 80 × 2

150

SQA100-1.6A

100

KWA 65 × 2

100

SQA150-1.6A

150

KWA 80 × 2

150

wall type

Fire pump adapter

SQB100-1.6A

100

KWS 65 × 2

100

SQB150-1.6A

150

KWS 80 × 2

150

Multi-use

Fire pump adapter

SQD100-1.6

100

KWS 65 × 2

100

SQD150-1.6

150

KWS 80 × 2

150

SQD100-1.6A

100

KWS 65 × 2

100

SQD150-1.6A

150

KWS 80 × 2

150

Above ground

Fire pump adapter

SQS100-2.5

100

2.5

KWS 65 × 2

100

SQS150-2.5

150

KWS 80 × 2

150

underground type

Fire pump adapter

SQA100-2.5

100

KWA 65 × 2

100

SQA150-2.5

150

KWA 80 × 2

150

Multi-use

Fire pump adapter

SQD100-2.5

100

KWS 65 × 2

100

SQD150-2.5

150

KWS 80 × 2

150

SQD100-2.5A

100

KWA 65 × 2

100

SQD150-2.5A

150

KWA 80 × 2

150

 

4. applicable places: water pump adapter is based on"Code for fire protection design of buildings"Fire fighting facilities for high-rise buildings. Usually within the building.automatic sprinkler systemOr connected to the water supply system of fire fighting equipment such as fire hydrants.

消防水泵接合器SQD100∕150-1.6A/2.5A.jpg