
Click image to enlarge
Multi-use fire pump adapter SQD100-2.5A
SQD100-2.5A
Retail price
$ 0
Market price
$ 0
Weight
0
kg
Stock
0
隐藏域元素占位
Key words:
Multi-use fire pump adapter
- Product Description
-
- Commodity name: Multi-use fire pump adapter SQD100-2.5A
- Commodity ID: SQD100-2.5A
1. model preparation:
Example: SQS100-1.6 indicates a ground fire pump adapter with nominal diameter of 100mm, nominal pressure of 1.6MPa and flange connection.
2. executive standard: GB3446-2013 "fire pump adapter"
3. parameters:
Product Name
Model specifications
Nominal diameter mm
Nominal pressure MPa
Water inlet interface specification
Diameter of outlet mm
Applicable media
Above ground
Fire pump adapter
SQS100-1.6
100
1.6
KWS 65 × 2
100
Water, foam mixture
SQS150-1.6
150
KWS 80 × 2
150
SQS100-1.6A
100
KWS 65 × 2
100
SQS150-1.6A
150
KWS 80 × 2
150
underground type
Fire pump adapter
SQA100-1.6
100
KWA 65 × 2
100
SQA150-1.6
150
KWA 80 × 2
150
SQA100-1.6A
100
KWA 65 × 2
100
SQA150-1.6A
150
KWA 80 × 2
150
wall type
Fire pump adapter
SQB100-1.6A
100
KWS 65 × 2
100
SQB150-1.6A
150
KWS 80 × 2
150
Multi-use
Fire pump adapter
SQD100-1.6
100
KWS 65 × 2
100
SQD150-1.6
150
KWS 80 × 2
150
SQD100-1.6A
100
KWS 65 × 2
100
SQD150-1.6A
150
KWS 80 × 2
150
Above ground
Fire pump adapter
SQS100-2.5
100
2.5
KWS 65 × 2
100
SQS150-2.5
150
KWS 80 × 2
150
underground type
Fire pump adapter
SQA100-2.5
100
KWA 65 × 2
100
SQA150-2.5
150
KWA 80 × 2
150
Multi-use
Fire pump adapter
SQD100-2.5
100
KWS 65 × 2
100
SQD150-2.5
150
KWS 80 × 2
150
SQD100-2.5A
100
KWA 65 × 2
100
SQD150-2.5A
150
KWA 80 × 2
150
4. applicable places: pump adapter is according to the "building design fire protection code" for high-rise building supporting fire facilities. It is usually connected to the water supply system of fire fighting equipment such as automatic sprinkler system or fire hydrant in the building.
Key words:- 消防器材
- 消防设备
- 福建消防器材
- 福建消防设备
1. model preparation:
Example: SQS100-1.6 indicates a ground fire pump adapter with nominal diameter of 100mm, nominal pressure of 1.6MPa and flange connection.
2. executive standard: GB3446-2013 "fire pump adapter"
3. parameters:
Product Name |
Model specifications |
Nominal diameter mm |
Nominal pressure MPa |
Water inlet interface specification |
Diameter of outlet mm |
Applicable media |
Above ground Fire pump adapter |
SQS100-1.6 |
100 |
1.6 |
KWS 65 × 2 |
100 |
Water, foam mixture |
SQS150-1.6 |
150 |
KWS 80 × 2 |
150 |
|||
SQS100-1.6A |
100 |
KWS 65 × 2 |
100 |
|||
SQS150-1.6A |
150 |
KWS 80 × 2 |
150 |
|||
underground type Fire pump adapter |
SQA100-1.6 |
100 |
KWA 65 × 2 |
100 |
||
SQA150-1.6 |
150 |
KWA 80 × 2 |
150 |
|||
SQA100-1.6A |
100 |
KWA 65 × 2 |
100 |
|||
SQA150-1.6A |
150 |
KWA 80 × 2 |
150 |
|||
wall type Fire pump adapter |
SQB100-1.6A |
100 |
KWS 65 × 2 |
100 |
||
SQB150-1.6A |
150 |
KWS 80 × 2 |
150 |
|||
Multi-use Fire pump adapter |
SQD100-1.6 |
100 |
KWS 65 × 2 |
100 |
||
SQD150-1.6 |
150 |
KWS 80 × 2 |
150 |
|||
SQD100-1.6A |
100 |
KWS 65 × 2 |
100 |
|||
SQD150-1.6A |
150 |
KWS 80 × 2 |
150 |
|||
Above ground Fire pump adapter |
SQS100-2.5 |
100 |
2.5 |
KWS 65 × 2 |
100 |
|
SQS150-2.5 |
150 |
KWS 80 × 2 |
150 |
|||
underground type Fire pump adapter |
SQA100-2.5 |
100 |
KWA 65 × 2 |
100 |
||
SQA150-2.5 |
150 |
KWA 80 × 2 |
150 |
|||
Multi-use Fire pump adapter |
SQD100-2.5 |
100 |
KWS 65 × 2 |
100 |
||
SQD150-2.5 |
150 |
KWS 80 × 2 |
150 |
|||
SQD100-2.5A |
100 |
KWA 65 × 2 |
100 |
|||
SQD150-2.5A |
150 |
KWA 80 × 2 |
150 |
4. applicable places: pump adapter is according to the "building design fire protection code" for high-rise building supporting fire facilities. It is usually connected to the water supply system of fire fighting equipment such as automatic sprinkler system or fire hydrant in the building.

Online Message
Product classification

Official website

Official account
Page Copyright © Water Power Fire Control Co.,Ltd
Address: No.57, Ximei Guifeng Industrial Zone, Quanzhou, Fujian, China