Click image to enlarge
Portable carbon dioxide fire extinguisher MT/3
MT/3
Retail price
Market price
Weight
kg
Stock
隐藏域元素占位
Key words:
Portable carbon dioxide fire extinguisher
- Product Description
-
- Commodity name: Portable carbon dioxide fire extinguisher MT/3
- Commodity ID: MT/3
1. model preparation:
Classification
Code of fire extinguishing agent
Meaning of fire extinguishing agent code
Specific extinguishing agent characteristic code
Meaning of feature code
Water-based fire extinguisher
S
Clear water or water with additives, but does not have foaming multiple and 25% liquid separation time requirements
AR (does not have this performance do not write)
Ability to extinguish water soluble liquid fuel fires
P
Foam fire extinguishing agent with foaming multiple and 25% liquid separation time requirements
AR (does not have this performance do not write)
Ability to extinguish water soluble liquid fuel fires
Dry powder fire extinguisher
F
Dry powder extinguishing agent. Including BC type and ABC type
ABC(BC dry powder extinguishing agent does not write)
Ability to extinguish Class A fires
Carbon dioxide fire extinguisher
T
carbon dioxide extinguishing agent
-
Clean gas fire extinguisher
J
clean gas extinguishing agent
-
3. Executive Standard: GB4351.1-2005 Portable Fire Extinguishers Part 1: Performance and Structural Requirements
GB4351.2-2005 Portable Fire Extinguishers-Part 2: Requirements for portable carbon dioxide seamless steel cylinders
4. technical parameters:
1. Portable dry powder fire extinguisher
Performance parameters
Model specifications
MFZ/ABC1
MFZ/ABC2
MFZ/ABC3
MFZ/ABC4
MFZ/ABC5
MFZ/ABC6
MFZ/ABC8
Filling quantity of fire extinguishing agent (Kg)
1±0.05
2±0.06
3±0.09
4±0.08
5±0.1
6±0.12
8±0.16
Filling pressure (MPa)
1.2
1.2
1.2
1.2
1.2
1.2
1.2
Effective spray distance (m)
≥ 3.0
≥ 3.0
≥ 3.5
≥ 3.5
≥ 3.5
≥ 4.0
≥ 4.5
Effective injection time (s)
≥ 8
≥ 8
≥ 13
≥ 13
≥ 13
≥ 13
≥ 15
Fire extinguishing level
1A,21B
1A,21B
2A,34B
2A,55B
3A,89B
3A,89B
4A,144B
Use temperature (℃)
-20~ 55
2. Portable water-based fire extinguisher
Performance parameters
Model specifications
MFA/2
MFA/3
MFA/6
MFA/9
MSWZ/2
MSWZ/3
MFA/6
MSWZ/9
Filling quantity of fire extinguishing agent (Kg)
Filling pressure (MPa)
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
Effective spray distance (m)
≥ 3.0
≥ 3.0
≥ 3.5
≥ 4.0
≥ 3.0
≥ 3.0
≥ 3.5
≥ 4.0
Effective injection time (s)
≥ 15
≥ 15
≥ 30
≥ 40
≥ 15
≥ 15
≥ 30
≥ 40
Fire extinguishing level
1A,55B,E
1A,55B,E
2A,89B,E
3A,113B,E
1A,55B,E
1A,55B,E
2A,89B,E
3A,113B,E
electrical insulation performance
≤ 36Kv
Use temperature (℃)
-20~ 55
5~ 55
3. Portable carbon dioxide fire extinguisher
Performance parameters
Model specifications
MT/2
MT/3
MT/5
MT/7
Filling quantity of fire extinguishing agent (Kg)
Filling coefficient
≤ 0.6
≤ 0.6
≤ 0.6
≤ 0.6
Effective spray distance (m)
≥ 2.0
≥ 2.0
≥ 2.5
≥ 2.5
Effective injection time (s)
≥ 8
≥ 8
≥ 8
≥ 9
Fire extinguishing level
21B,C,E
21B,C,E
34B,C,E
55B,C,E
Use temperature (℃)
-10~ 55
4. Wheeled dry powder fire extinguisher
Performance parameters
Model specifications
MFTZ/ABC20
MFTZ/ABC25
MFTZ/ABC35
MFZ/ABC50
MFZ/ABC70
Filling quantity of fire extinguishing agent (Kg)
20±0.4
25±0.5
35±0.7
50±1.0
70±1.4
Filling pressure (MPa)
1.2
1.2
1.2
1.2
1.2
Effective spray distance (m)
≥ 6.0
≥ 6.0
≥ 6.0
≥ 6.0
≥ 6.0
Effective injection time (s)
≥ 30
≥ 30
≥ 30
≥ 30
≥ 30
Fire extinguishing level
6A,144B,C ,E
6A,183B,C ,E
10A,233B,C ,E
15A,297B,C ,E
15A,297B,C ,E
Use temperature (℃)
-20~ 55
5. Wheeled water-based fire extinguisher
Performance parameters
Model specifications
MFA/25
MFA/45
MFA/65
Filling quantity of fire extinguishing agent (Kg)
Filling pressure (MPa)
1.2
1.2
1.2
Effective spray distance (m)
≥ 3.0
≥ 3.0
≥ 3.0
Effective injection time (s)
40 ≤ S≤ 210
40 ≤ S≤ 210
40 ≤ S≤ 210
Fire extinguishing level
4A,183B
6A,233B
6A,297B
electrical insulation performance
≤ 36Kv
Use temperature (℃)
-20~ 55
6. Cart-type carbon dioxide fire extinguisher
Performance parameters
Model specifications
MTT/10
MTT/20
MTT/24
MTT/30
MTT/40
Filling quantity of fire extinguishing agent (Kg)
Filling coefficient
≤ 0.74
Effective spray distance (m)
≥ 6
Effective injection time (s)
≥ 20
Fire extinguishing level
55B,E
70B,E
89B,E
89B,E
113B,E
Use temperature (℃)
-10~ 55
7. Simple water-based fire extinguisher
Model specifications
Fire extinguishing agent filling quantity
ml
Filling pressure
MPa
effective injection time
s
Effective spray distance
m
Fire extinguishing level
Use temperature (℃)
MSWJ580
5800-29
1.2
≥ 5
≥ 2
0.5A, 8B, E, 5F
5~ 55
MSWJ950
9500-47.5
1.2
≥ 5
≥ 2
0.5A, 21B, E, 5F
1. model preparation:
Classification |
Code of fire extinguishing agent |
Meaning of fire extinguishing agent code |
Specific extinguishing agent characteristic code |
Meaning of feature code |
Water-based fire extinguisher |
S |
Clear water or water with additives, but does not have foaming multiple and 25% liquid separation time requirements |
AR (does not have this performance do not write) |
Ability to extinguish water soluble liquid fuel fires |
P |
Foam fire extinguishing agent with foaming multiple and 25% liquid separation time requirements |
AR (does not have this performance do not write) |
Ability to extinguish water soluble liquid fuel fires |
|
Dry powder fire extinguisher |
F |
Dry powder extinguishing agent. Including BC type and ABC type |
ABC(BC dry powder extinguishing agent does not write) |
Ability to extinguish Class A fires |
Carbon dioxide fire extinguisher |
T |
carbon dioxide extinguishing agent |
- |
|
Clean gas fire extinguisher |
J |
clean gas extinguishing agent |
- |
|
3. Executive Standard: GB4351.1-2005 Portable Fire Extinguishers Part 1: Performance and Structural Requirements
GB4351.2-2005 Portable Fire Extinguishers-Part 2: Requirements for portable carbon dioxide seamless steel cylinders
4. technical parameters:
1. Portable dry powder fire extinguisher
Performance parameters Model specifications |
MFZ/ABC1 |
MFZ/ABC2 |
MFZ/ABC3 |
MFZ/ABC4 |
MFZ/ABC5 |
MFZ/ABC6 |
MFZ/ABC8 |
Filling quantity of fire extinguishing agent (Kg) |
1±0.05 |
2±0.06 |
3±0.09 |
4±0.08 |
5±0.1 |
6±0.12 |
8±0.16 |
Filling pressure (MPa) |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
Effective spray distance (m) |
≥ 3.0 |
≥ 3.0 |
≥ 3.5 |
≥ 3.5 |
≥ 3.5 |
≥ 4.0 |
≥ 4.5 |
Effective injection time (s) |
≥ 8 |
≥ 8 |
≥ 13 |
≥ 13 |
≥ 13 |
≥ 13 |
≥ 15 |
Fire extinguishing level |
1A,21B |
1A,21B |
2A,34B |
2A,55B |
3A,89B |
3A,89B |
4A,144B |
Use temperature (℃) |
-20~ 55 |
2. Portable water-based fire extinguisher
Performance parameters Model specifications |
MFA/2 |
MFA/3 |
MFA/6 |
MFA/9 |
MSWZ/2 |
MSWZ/3 |
MFA/6 |
MSWZ/9 |
Filling quantity of fire extinguishing agent (Kg) |
![]() |
![]() |
|
|
|
|
|
|
Filling pressure (MPa) |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
Effective spray distance (m) |
≥ 3.0 |
≥ 3.0 |
≥ 3.5 |
≥ 4.0 |
≥ 3.0 |
≥ 3.0 |
≥ 3.5 |
≥ 4.0 |
Effective injection time (s) |
≥ 15 |
≥ 15 |
≥ 30 |
≥ 40 |
≥ 15 |
≥ 15 |
≥ 30 |
≥ 40 |
Fire extinguishing level |
1A,55B,E |
1A,55B,E |
2A,89B,E |
3A,113B,E |
1A,55B,E |
1A,55B,E |
2A,89B,E |
3A,113B,E |
electrical insulation performance |
≤ 36Kv |
|||||||
Use temperature (℃) |
-20~ 55 |
5~ 55 |
3. Portable carbon dioxide fire extinguisher
Performance parameters Model specifications |
MT/2 |
MT/3 |
MT/5 |
MT/7 |
Filling quantity of fire extinguishing agent (Kg) |
|
|
|
|
Filling coefficient |
≤ 0.6 |
≤ 0.6 |
≤ 0.6 |
≤ 0.6 |
Effective spray distance (m) |
≥ 2.0 |
≥ 2.0 |
≥ 2.5 |
≥ 2.5 |
Effective injection time (s) |
≥ 8 |
≥ 8 |
≥ 8 |
≥ 9 |
Fire extinguishing level |
21B,C,E |
21B,C,E |
34B,C,E |
55B,C,E |
Use temperature (℃) |
-10~ 55 |
4. Wheeled dry powder fire extinguisher
Performance parameters Model specifications |
MFTZ/ABC20 |
MFTZ/ABC25 |
MFTZ/ABC35 |
MFZ/ABC50 |
MFZ/ABC70 |
Filling quantity of fire extinguishing agent (Kg) |
20±0.4 |
25±0.5 |
35±0.7 |
50±1.0 |
70±1.4 |
Filling pressure (MPa) |
1.2 |
1.2 |
1.2 |
1.2 |
1.2 |
Effective spray distance (m) |
≥ 6.0 |
≥ 6.0 |
≥ 6.0 |
≥ 6.0 |
≥ 6.0 |
Effective injection time (s) |
≥ 30 |
≥ 30 |
≥ 30 |
≥ 30 |
≥ 30 |
Fire extinguishing level |
6A,144B,C ,E |
6A,183B,C ,E |
10A,233B,C ,E |
15A,297B,C ,E |
15A,297B,C ,E |
Use temperature (℃) |
-20~ 55 |
5. Wheeled water-based fire extinguisher
Performance parameters Model specifications |
MFA/25 |
MFA/45 |
MFA/65 |
|
Filling quantity of fire extinguishing agent (Kg) |
|
|
|
|
Filling pressure (MPa) |
1.2 |
1.2 |
1.2 |
|
Effective spray distance (m) |
≥ 3.0 |
≥ 3.0 |
≥ 3.0 |
|
Effective injection time (s) |
40 ≤ S≤ 210 |
40 ≤ S≤ 210 |
40 ≤ S≤ 210 |
|
Fire extinguishing level |
4A,183B |
6A,233B |
6A,297B |
|
electrical insulation performance |
≤ 36Kv |
|
||
Use temperature (℃) |
-20~ 55 |
|
||
6. Cart-type carbon dioxide fire extinguisher
Performance parameters Model specifications |
MTT/10 |
MTT/20 |
MTT/24 |
MTT/30 |
MTT/40 |
Filling quantity of fire extinguishing agent (Kg) |
|
|
|
|
|
Filling coefficient |
≤ 0.74 |
||||
Effective spray distance (m) |
≥ 6 |
||||
Effective injection time (s) |
≥ 20 |
||||
Fire extinguishing level |
55B,E |
70B,E |
89B,E |
89B,E |
113B,E |
Use temperature (℃) |
-10~ 55 |
|
7. Simple water-based fire extinguisher
Model specifications |
Fire extinguishing agent filling quantity ml |
Filling pressure MPa |
effective injection time s |
Effective spray distance m |
Fire extinguishing level |
Use temperature (℃) |
MSWJ580 |
5800-29 |
1.2 |
≥ 5 |
≥ 2 |
0.5A, 8B, E, 5F |
5~ 55 |
MSWJ950 |
9500-47.5 |
1.2 |
≥ 5 |
≥ 2 |
0.5A, 21B, E, 5F |

Online Message
Product classification

Official website

Official account
Page Copyright © Water Power Fire Control Co.,Ltd