Product classification


undefined
+
  • undefined

Click image to enlarge

No.:

PF5~16(20,25,30,40,50)

Dry powder monitor PF5 ~ 16(20,25,30,40,50)

PF5~16(20,25,30,40,50)

Retail price

Market price


Weight

kg

Quantity
-
+

Stock

隐藏域元素占位

Classification:

Key words:

Dry Powder Cannon

  • Product Description
    • Commodity name: Dry powder monitor PF5 ~ 16(20,25,30,40,50)
    • Commodity ID: PF5~16(20,25,30,40,50)

    1. model preparation:

     

    1. Class and group code
    PS-fire water cannon;
    PP-fire foam gun;
    PF-fire dry powder monitor;
    PM -- Pulse fire water monitor;
    PL-dual-purpose fire monitor;
    PZ-combined fire monitor.

    2. Feature code
    KD-electric control (referred to as electric control or electric);
    KY-hydraulic control (referred to as hydraulic control or hydraulic);
    KQ-Pneumatic control (referred to as pneumatic control or pneumatic);
    Y-Mobile;
    Fixed slightly.

    3. Description of main parameter preparation:



    Example: PS8/30WB means that the spray medium is water, the rated flow rate is 30L/s, the rated working pressure is 0.8MPa, and the fixed manual fire water with spray function
    Cannon.

    PSKD10/50WG indicates that the injection medium is water or foam mixture, the rated flow rate is 50L/s, the rated working pressure is 1.0MPa, and the fixed electronically controlled fire water monitor with spray and explosion-proof functions.

    PLKDY8/40WB indicates that the injection medium is water, the rated flow rate is 40L/s, and the rated working pressure is 0.8MPa.

     

    2. implementation standard: GB19156-2019 "fire cannon"

     

    3. parameters:

     

    1. Fixed manual fire water monitor

    Performance parameters, specifications and models

    PS8/30W PS8/40W PS8/50W PS8/60W PS8/80W PS10/100W PS10/120W
    Rated pressure (MPa) 0.8 1.0
    Working pressure range (MPa) 0.8~1.6 1.0~1.6
    Rated flow (L/S) 30 40 50 60 80 100 120
    Range (M) ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 90 ≥ 95
    Maximum spray angle (°) ≥ 90
    Pitch angle (°) -85~ 90
    Horizontal rotation angle (°) 360
    Connecting flange DN100 PN16 DN150 PN16

    2. Fixed manual fire dual-purpose gun

    Performance parameter model model specification PL8/24 PL8/32 PL8/40 PL8/48 PL8/64 PL8/80 PL10/100
    Rated working pressure (Mpa) 0.8 1.0
    Working pressure range (Mpa) 0.8~1.6 1.0~1.6
    Rated flow (L/S) 24 32 40 48 64 80 100
    Range (M) Water ≥ 55 ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 90
    Bubble ≥ 42 ≥ 48 ≥ 55 ≥ 60 ≥ 70 ≥ 80 ≥ 85
    Maximum spray angle (°) ≥ 120
    Pitch angle (°) 30~ 70
    Horizontal rotation angle (°) 360
    Connecting flange DN100 PN16

    3. Fixed manual fire dry powder gun

    Performance parameters Model specifications PF5-16/10 PF5-16/20 PF5-16/25 PF5-16/30 PF5-16/35 PF5-16/40 PF5-16/45 PF5-16/50
    Working pressure range (Mpa) 0.5~1.6
    Rated injection rate (Kg/S) 10 20 25 30 35 40 45 50
    Range (M) ≥ 18 ≥ 20 ≥ 30 ≥ 35 ≥ 38 ≥ 40 ≥ 45 ≥ 50
    Pitch angle (°) -85~ 90
    Horizontal rotation angle (°) 360
    Connecting flange DN100 PN16

    4. Fixed explosion-proof electric fire water monitor

    Performance parameters, specifications and models PSKD8/20W(G) PSKD8/25WG PSKD8/30WG PSKD8/40WG PSKD8/50WG PSKD8/60WG PSKD8/80WG
    Rated pressure (Mpa) 0.8
    Working pressure range (Mpa) 0.8~1.6
    Rated flow (L/S) 20 25 30 40 50 60 80
    Range (M) ≥ 50 ≥ 55 ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85
    Maximum spray angle (°) ≥ 90
    Pitch angle (°) -85~ 90
    Horizontal rotation angle (°) 360
    Electric power supply used AC380V、AC220V、DC24V
    Radius distance of wireless remote control (M) ≥ 150
    Connecting flange DN100 PN16
    Performance parameters, specifications and models PSKD10/100WG PSKD10/120WG PSKD10/150WG PSKD12/180WG PSKD12/200WG PSKD12/250WG PSKD12/300WG
    Rated pressure (Mpa) 1.0 1.2
    Working pressure range (Mpa) 1.0~1.6 1.2~1.6
    Rated flow (L/S) 100 120 150 180 200 250 300
    Range (M) ≥ 90 ≥ 95 ≥ 100 ≥ 105 ≥ 110 ≥ 115 ≥ 120
    Maximum spray angle (°) ≥ 90
    Pitch angle (°) -85~ 90
    Horizontal rotation angle (°) 360
    Electric power supply used AC380V、AC220V、DC24V
    Radius distance of wireless remote control (M) ≥ 150
    Connecting flange DN100 PN16 DN150 PN16 DN200 PN16

    5. Fixed explosion-proof electric control dual-purpose fire monitor

    Performance parameter model model specification PLKD8/32G PLKD8/40G PLKD8/48G PLKD8/64G PLKD8/80G PLKD10/100G PLKD10/120G PLKD12/200G
    Rated working pressure (Mpa) 0.8 1.0 1.2
    Working pressure range (Mpa) 0.8~1.6 1.0~1.6 1.2~1.6
    Rated flow (L/S) 32 40 48 64 80 100 100 200
    Range (M) Water ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 90 ≥ 95 ≥ 110
    Bubble ≥ 48 ≥ 55 ≥ 60 ≥ 70 ≥ 80 ≥ 85 ≥ 90 ≥ 105
    Maximum spray angle (°) ≥ 120
    Pitch angle (°) 30~ 70
    Horizontal rotation angle (°) 360
    Electric power supply used AC380V、AC220V、DC24V
    Radius distance of wireless remote control (M) ≥ 150
    Connecting flange DN100 PN16 DN150 PN16

    6. Fixed explosion-proof electric control fire dry powder gun

    Performance parameters Model specifications PFKD5-16/10G PFKD5-16/20G PFKD5-16/25G PFKD5-16/30G PFKD5-16/35G PFKD5-16/40G PFKD5-16/45G PFKD5-16/50G
    Working pressure range (Mpa) 0.5~1.6
    Rated injection rate (Kg/S) 10 20 25 30 35 40 45 50
    Range (M) ≥ 18 ≥ 20 ≥ 30 ≥ 35 ≥ 38 ≥ 40 ≥ 45 ≥ 50
    Pitch angle (°) -85~ 90
    Horizontal rotation angle (°) 360
    Electric power supply used AC380V、AC220V、DC24V
    Radius distance of wireless remote control (M) ≥ 150
    Connecting flange Flange DN100 PN16 (HG/T20592-2009)

    7. Fixed combined electric control fire monitor

    Performance parameter model model specification PZKD10·5~15/80·30W PZKD10·5~15/80·30WG PZKD10·5~15/120·30W PZKD10·5~15/120·30WG PZKD10·5~15/150·30W PZKD10·5~15/150·30WG
    Rated working pressure (Mpa) Water 1.0 1.0 1.0
    Dry Powder /
    Working pressure range (Mpa) Water 0.8~1.6
    Dry Powder 0.5~1.6
    Rated flow (L/S) 80 120 150
    Rated injection rate (Kg/s) 30
    Range (M) Water ≥ 85 ≥ 95 ≥ 100
    Dry Powder ≥ 35
    Mixed spray ≥ 70 ≥ 80 ≥ 85
    Maximum spray angle (°) ≥ 90
    Pitch angle (°) -85~ 90
    Horizontal rotation angle (°) 360
    Electric power supply used AC380V、AC220V、DC24V
    Radius distance of wireless remote control (M) ≥ 150
    Connecting flange DN150 PN16

    8. Mobile manual fire monitor

    Performance parameter model model specification PSY8/20W PSY8/30W PSY8/40W PSY8/50W PLY8/24 PLY8/32 PLY8/40 PLY8/48
    Rated working pressure (Mpa) 0.8
    Working pressure range (Mpa) 0.8~1.2
    Rated flow (L/S) 20 30 40 50 24 32 40 48
    Range (M) Water ≥ 50 ≥ 60 ≥ 65 ≥ 70 ≥ 55 ≥ 60 ≥ 65 ≥ 70
    Bubble / / / / ≥ 42 ≥ 48 ≥ 55 ≥ 60
    Maximum spray angle (°) ≥ 120
    Pitch angle (°) 30~ 70
    Horizontal rotation angle (°) 90
    Connection mode Optional

    9. Mobile electric control fire monitor

    Performance parameter model model specification PSKDY8/30WB PSKDY8/40WB PSKDY8/50WB PSKDY8/60WB PSKDY8/80WB PLKDY8/32B PLKDY8/40B PLKDY8/48B PLKDY8/64B PLKDY8/80ZB
    Rated working pressure (Mpa) 0.8
    Working pressure range (Mpa) 0.8~1.2
    Rated flow (L/S) 30 40 50 60 80 32 40 48 64 80
    Range (M) Water ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85
    Bubble / / / / ≥ 48 ≥ 55 ≥ 60 ≥ 70 ≥ 80
    Maximum spray angle (°) ≥ 120
    Pitch angle (°) 30~ 70
    Horizontal rotation angle (°) 90
    Electric power supply used DC24V
    Radius distance of wireless remote control (m) ≥ 150
    Connection mode Optional

    4. applicable places: applicable to petrochemical enterprises, storage tank areas, airports, warehouses, ports, ships, offshore fixed platforms and fire engines and other facilities.

1. model preparation:

 

1. Class and group code
PS-fire water cannon;
PP-fire foam gun;
PF-fire dry powder monitor;
PM -- Pulse fire water monitor;
PL-dual-purpose fire monitor;
PZ-combined fire monitor.

2. Feature code
KD-electric control (referred to as electric control or electric);
KY-hydraulic control (referred to as hydraulic control or hydraulic);
KQ-Pneumatic control (referred to as pneumatic control or pneumatic);
Y-Mobile;
Fixed slightly.

3. Description of main parameter preparation:



Example: PS8/30WB means that the spray medium is water, the rated flow rate is 30L/s, the rated working pressure is 0.8MPa, and the fixed manual fire water with spray function
Cannon.

PSKD10/50WG indicates that the injection medium is water or foam mixture, the rated flow rate is 50L/s, the rated working pressure is 1.0MPa, and the fixed electronically controlled fire water monitor with spray and explosion-proof functions.

PLKDY8/40WB indicates that the injection medium is water, the rated flow rate is 40L/s, and the rated working pressure is 0.8MPa.

 

2. implementation standard: GB19156-2019 "fire cannon"

 

3. parameters:

 

1. Fixed manual fire water monitor

Performance parameters, specifications and models

PS8/30W PS8/40W PS8/50W PS8/60W PS8/80W PS10/100W PS10/120W
Rated pressure (MPa) 0.8 1.0
Working pressure range (MPa) 0.8~1.6 1.0~1.6
Rated flow (L/S) 30 40 50 60 80 100 120
Range (M) ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 90 ≥ 95
Maximum spray angle (°) ≥ 90
Pitch angle (°) -85~ 90
Horizontal rotation angle (°) 360
Connecting flange DN100 PN16 DN150 PN16

2. Fixed manual fire dual-purpose gun

Performance parameter model model specification PL8/24 PL8/32 PL8/40 PL8/48 PL8/64 PL8/80 PL10/100
Rated working pressure (Mpa) 0.8 1.0
Working pressure range (Mpa) 0.8~1.6 1.0~1.6
Rated flow (L/S) 24 32 40 48 64 80 100
Range (M) Water ≥ 55 ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 90
Bubble ≥ 42 ≥ 48 ≥ 55 ≥ 60 ≥ 70 ≥ 80 ≥ 85
Maximum spray angle (°) ≥ 120
Pitch angle (°) 30~ 70
Horizontal rotation angle (°) 360
Connecting flange DN100 PN16

3. Fixed manual fire dry powder gun

Performance parameters Model specifications PF5-16/10 PF5-16/20 PF5-16/25 PF5-16/30 PF5-16/35 PF5-16/40 PF5-16/45 PF5-16/50
Working pressure range (Mpa) 0.5~1.6
Rated injection rate (Kg/S) 10 20 25 30 35 40 45 50
Range (M) ≥ 18 ≥ 20 ≥ 30 ≥ 35 ≥ 38 ≥ 40 ≥ 45 ≥ 50
Pitch angle (°) -85~ 90
Horizontal rotation angle (°) 360
Connecting flange DN100 PN16

4. Fixed explosion-proof electric fire water monitor

Performance parameters, specifications and models PSKD8/20W(G) PSKD8/25WG PSKD8/30WG PSKD8/40WG PSKD8/50WG PSKD8/60WG PSKD8/80WG
Rated pressure (Mpa) 0.8
Working pressure range (Mpa) 0.8~1.6
Rated flow (L/S) 20 25 30 40 50 60 80
Range (M) ≥ 50 ≥ 55 ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85
Maximum spray angle (°) ≥ 90
Pitch angle (°) -85~ 90
Horizontal rotation angle (°) 360
Electric power supply used AC380V、AC220V、DC24V
Radius distance of wireless remote control (M) ≥ 150
Connecting flange DN100 PN16
Performance parameters, specifications and models PSKD10/100WG PSKD10/120WG PSKD10/150WG PSKD12/180WG PSKD12/200WG PSKD12/250WG PSKD12/300WG
Rated pressure (Mpa) 1.0 1.2
Working pressure range (Mpa) 1.0~1.6 1.2~1.6
Rated flow (L/S) 100 120 150 180 200 250 300
Range (M) ≥ 90 ≥ 95 ≥ 100 ≥ 105 ≥ 110 ≥ 115 ≥ 120
Maximum spray angle (°) ≥ 90
Pitch angle (°) -85~ 90
Horizontal rotation angle (°) 360
Electric power supply used AC380V、AC220V、DC24V
Radius distance of wireless remote control (M) ≥ 150
Connecting flange DN100 PN16 DN150 PN16 DN200 PN16

5. Fixed explosion-proof electric control dual-purpose fire monitor

Performance parameter model model specification PLKD8/32G PLKD8/40G PLKD8/48G PLKD8/64G PLKD8/80G PLKD10/100G PLKD10/120G PLKD12/200G
Rated working pressure (Mpa) 0.8 1.0 1.2
Working pressure range (Mpa) 0.8~1.6 1.0~1.6 1.2~1.6
Rated flow (L/S) 32 40 48 64 80 100 100 200
Range (M) Water ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 90 ≥ 95 ≥ 110
Bubble ≥ 48 ≥ 55 ≥ 60 ≥ 70 ≥ 80 ≥ 85 ≥ 90 ≥ 105
Maximum spray angle (°) ≥ 120
Pitch angle (°) 30~ 70
Horizontal rotation angle (°) 360
Electric power supply used AC380V、AC220V、DC24V
Radius distance of wireless remote control (M) ≥ 150
Connecting flange DN100 PN16 DN150 PN16

6. Fixed explosion-proof electric control fire dry powder gun

Performance parameters Model specifications PFKD5-16/10G PFKD5-16/20G PFKD5-16/25G PFKD5-16/30G PFKD5-16/35G PFKD5-16/40G PFKD5-16/45G PFKD5-16/50G
Working pressure range (Mpa) 0.5~1.6
Rated injection rate (Kg/S) 10 20 25 30 35 40 45 50
Range (M) ≥ 18 ≥ 20 ≥ 30 ≥ 35 ≥ 38 ≥ 40 ≥ 45 ≥ 50
Pitch angle (°) -85~ 90
Horizontal rotation angle (°) 360
Electric power supply used AC380V、AC220V、DC24V
Radius distance of wireless remote control (M) ≥ 150
Connecting flange Flange DN100 PN16 (HG/T20592-2009)

7. Fixed combined electric control fire monitor

Performance parameter model model specification PZKD10·5~15/80·30W PZKD10·5~15/80·30WG PZKD10·5~15/120·30W PZKD10·5~15/120·30WG PZKD10·5~15/150·30W PZKD10·5~15/150·30WG
Rated working pressure (Mpa) Water 1.0 1.0 1.0
Dry Powder /
Working pressure range (Mpa) Water 0.8~1.6
Dry Powder 0.5~1.6
Rated flow (L/S) 80 120 150
Rated injection rate (Kg/s) 30
Range (M) Water ≥ 85 ≥ 95 ≥ 100
Dry Powder ≥ 35
Mixed spray ≥ 70 ≥ 80 ≥ 85
Maximum spray angle (°) ≥ 90
Pitch angle (°) -85~ 90
Horizontal rotation angle (°) 360
Electric power supply used AC380V、AC220V、DC24V
Radius distance of wireless remote control (M) ≥ 150
Connecting flange DN150 PN16

8. Mobile manual fire monitor

Performance parameter model model specification PSY8/20W PSY8/30W PSY8/40W PSY8/50W PLY8/24 PLY8/32 PLY8/40 PLY8/48
Rated working pressure (Mpa) 0.8
Working pressure range (Mpa) 0.8~1.2
Rated flow (L/S) 20 30 40 50 24 32 40 48
Range (M) Water ≥ 50 ≥ 60 ≥ 65 ≥ 70 ≥ 55 ≥ 60 ≥ 65 ≥ 70
Bubble / / / / ≥ 42 ≥ 48 ≥ 55 ≥ 60
Maximum spray angle (°) ≥ 120
Pitch angle (°) 30~ 70
Horizontal rotation angle (°) 90
Connection mode Optional

9. Mobile electric control fire monitor

Performance parameter model model specification PSKDY8/30WB PSKDY8/40WB PSKDY8/50WB PSKDY8/60WB PSKDY8/80WB PLKDY8/32B PLKDY8/40B PLKDY8/48B PLKDY8/64B PLKDY8/80ZB
Rated working pressure (Mpa) 0.8
Working pressure range (Mpa) 0.8~1.2
Rated flow (L/S) 30 40 50 60 80 32 40 48 64 80
Range (M) Water ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85 ≥ 60 ≥ 65 ≥ 70 ≥ 75 ≥ 85
Bubble / / / / ≥ 48 ≥ 55 ≥ 60 ≥ 70 ≥ 80
Maximum spray angle (°) ≥ 120
Pitch angle (°) 30~ 70
Horizontal rotation angle (°) 90
Electric power supply used DC24V
Radius distance of wireless remote control (m) ≥ 150
Connection mode Optional

4. applicable places: applicable to petrochemical enterprises, storage tank areas, airports, warehouses, ports, ships, offshore fixed platforms and fire engines and other facilities.