Click image to enlarge
Pressure proportional mixing device (horizontal) PHYML48/80(6%)
PHYML48/80(6%)
Retail price
$ 0
Market price
$ 0
Weight
0
kg
Stock
0
隐藏域元素占位
Key words:
Pressure proportional mixing device
- Product Description
-
- Commodity name: Pressure proportional mixing device (horizontal) PHYML48/80(6%)
- Commodity ID: PHYML48/80(6%)
1. model preparation:
Example: PHYM48/50 means the maximum mixed liquid flow rate is 48L/s, the storage tank is a diaphragm type, and the volume is 5 cubic pressure type proportional mixing device.
2. executive standard: GB20031-2005 General Technical Conditions for Foam Fire Extinguishing Systems and Components
3. technical parameters:
Performance parameters
Specifications and models
Rated working pressure
(MPa)
Working pressure range
(MPa)
Maximum mixed liquid flow (L/s)
Mixture flow range
(L/s)
mixing ratio
(%)
Pressure drop
(MPa)
Tank volume
(L)
PHYML32/10
1.2
or
1.6
0.6~1.2
or
0.6~1.6
32
4~32
3~3.9
or
6~7
<0.15
1000
PHYML32/15
1500
PHYML32/20
2000
PHYML32/30
3000
PHYM48/40
48
16~48
4000
PHYM48/50
5000
PHYM48/60
6000
PHYM80/80
80
24~80
8000
Key words:- 消防器材
- 消防设备
- 福建消防器材
- 福建消防设备
- 消防器材销售
1. model preparation:
Example: PHYM48/50 means the maximum mixed liquid flow rate is 48L/s, the storage tank is a diaphragm type, and the volume is 5 cubic pressure type proportional mixing device.
2. executive standard: GB20031-2005 General Technical Conditions for Foam Fire Extinguishing Systems and Components
3. technical parameters:
Performance parameters
Specifications and models |
Rated working pressure (MPa) |
Working pressure range (MPa) |
Maximum mixed liquid flow (L/s) |
Mixture flow range (L/s) |
mixing ratio (%) |
Pressure drop (MPa) |
Tank volume (L) |
PHYML32/10 |
1.2 or 1.6 |
0.6~1.2 or 0.6~1.6
|
32 |
4~32 |
3~3.9 or 6~7 |
<0.15 |
1000 |
PHYML32/15 |
1500 |
||||||
PHYML32/20 |
2000 |
||||||
PHYML32/30 |
3000 |
||||||
PHYM48/40 |
48 |
16~48 |
4000 |
||||
PHYM48/50 |
5000 |
||||||
PHYM48/60 |
6000 |
||||||
PHYM80/80 |
80 |
24~80 |
8000 |
4. applicable places: widely used to put out A (except liquefied gas), B, C liquid fire, is the most commonly used fire fighting equipment in oil depots, refineries, chemical plants, oil fields, docks, oil tankers, aircraft hangars, airports, underground parking plants and fuel boiler rooms.

Online Message
Product classification

Official website

Official account
Page Copyright © Water Power Fire Control Co.,Ltd
Address: No.57, Ximei Guifeng Industrial Zone, Quanzhou, Fujian, China