Product classification


undefined
+
  • undefined

Click image to enlarge

No.:

MFTZ-ABC20

Wheeled dry powder fire extinguisher MFTZ-ABC20

MFTZ-ABC20

Retail price

Market price


Weight

kg

Quantity
-
+

Stock

隐藏域元素占位

Key words:

Wheeled dry powder fire extinguisher

  • Product Description
    • Commodity name: Wheeled dry powder fire extinguisher MFTZ-ABC20
    • Commodity ID: MFTZ-ABC20

    1. model preparation:


    Classification

    Code of fire extinguishing agent

    Meaning of fire extinguishing agent code

    Specific extinguishing agent characteristic code

    Meaning of feature code

    Water-based fire extinguisher

    S

    Clear water or water with additives, but does not have foaming multiple and 25% liquid separation time requirements

    AR (does not have this performance do not write)

    Ability to extinguish water soluble liquid fuel fires

    P

    Foam fire extinguishing agent with foaming multiple and 25% liquid separation time requirements

    AR (does not have this performance do not write)

    Ability to extinguish water soluble liquid fuel fires

    Dry powder fire extinguisher

    F

    Dry powder extinguishing agent. Including BC type and ABC type

    ABC(BC dry powder extinguishing agent does not write)

    Ability to extinguish Class A fires

    Carbon dioxide fire extinguisher

    T

    carbon dioxide extinguishing agent

    -

     

    Clean gas fire extinguisher

    J

    clean gas extinguishing agent

    -

     

     

    3. Executive Standard: GB4351.1-2005 Portable Fire Extinguishers Part 1: Performance and Structural Requirements
    GB4351.2-2005 Portable Fire Extinguishers-Part 2: Requirements for portable carbon dioxide seamless steel cylinders

     

    4. technical parameters:

     

     

     

    1. Portable dry powder fire extinguisher

     

     

    Performance parameters

    Model specifications

    MFZ/ABC1

    MFZ/ABC2

    MFZ/ABC3

    MFZ/ABC4

    MFZ/ABC5

    MFZ/ABC6

    MFZ/ABC8

    Filling quantity of fire extinguishing agent (Kg)

    1±0.05

    2±0.06

    3±0.09

    4±0.08

    5±0.1

    6±0.12

    8±0.16

    Filling pressure (MPa)

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    Effective spray distance (m)

    ≥ 3.0

    ≥ 3.0

    ≥ 3.5

    ≥ 3.5

    ≥ 3.5

    ≥ 4.0

    ≥ 4.5

    Effective injection time (s)

    ≥ 8

    ≥ 8

    ≥ 13

    ≥ 13

    ≥ 13

    ≥ 13

    ≥ 15

    Fire extinguishing level

    1A,21B

    1A,21B

    2A,34B

    2A,55B

    3A,89B

    3A,89B

    4A,144B

    Use temperature (℃)

    -20~ 55

     

    2. Portable water-based fire extinguisher

     

     

    Performance parameters

    Model specifications

    MFA/2

    MFA/3

    MFA/6

    MFA/9

    MSWZ/2

    MSWZ/3

    MFA/6

    MSWZ/9

    Filling quantity of fire extinguishing agent (Kg)

    Filling pressure (MPa)

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    Effective spray distance (m)

    ≥ 3.0

    ≥ 3.0

    ≥ 3.5

    ≥ 4.0

    ≥ 3.0

    ≥ 3.0

    ≥ 3.5

    ≥ 4.0

    Effective injection time (s)

    ≥ 15

    ≥ 15

    ≥ 30

    ≥ 40

    ≥ 15

    ≥ 15

    ≥ 30

    ≥ 40

    Fire extinguishing level

    1A,55B,E

    1A,55B,E

    2A,89B,E

    3A,113B,E

    1A,55B,E

    1A,55B,E

    2A,89B,E

    3A,113B,E

    electrical insulation performance

    ≤ 36Kv

    Use temperature (℃)

    -20~ 55

    5~ 55

     

    3. Portable carbon dioxide fire extinguisher

     

     

    Performance parameters

    Model specifications

    MT/2

    MT/3

    MT/5

    MT/7

    Filling quantity of fire extinguishing agent (Kg)

    Filling coefficient

    ≤ 0.6

    ≤ 0.6

    ≤ 0.6

    ≤ 0.6

    Effective spray distance (m)

    ≥ 2.0

    ≥ 2.0

    ≥ 2.5

    ≥ 2.5

    Effective injection time (s)

    ≥ 8

    ≥ 8

    ≥ 8

    ≥ 9

    Fire extinguishing level

    21B,C,E

    21B,C,E

    34B,C,E

    55B,C,E

    Use temperature (℃)

    -10~ 55

     

    4. Wheeled dry powder fire extinguisher

     

     

    Performance parameters

    Model specifications

    MFTZ/ABC20

    MFTZ/ABC25

    MFTZ/ABC35

    MFZ/ABC50

    MFZ/ABC70

    Filling quantity of fire extinguishing agent (Kg)

    20±0.4

    25±0.5

    35±0.7

    50±1.0

    70±1.4

    Filling pressure (MPa)

    1.2

    1.2

    1.2

    1.2

    1.2

    Effective spray distance (m)

    ≥ 6.0

    ≥ 6.0

    ≥ 6.0

    ≥ 6.0

    ≥ 6.0

    Effective injection time (s)

    ≥ 30

    ≥ 30

    ≥ 30

    ≥ 30

    ≥ 30

    Fire extinguishing level

    6A,144B,C ,E

    6A,183B,C ,E

    10A,233B,C ,E

    15A,297B,C ,E

    15A,297B,C ,E

    Use temperature (℃)

    -20~ 55

     

    5. Wheeled water-based fire extinguisher

     

     

    Performance parameters

    Model specifications

    MFA/25

    MFA/45

    MFA/65

    Filling quantity of fire extinguishing agent (Kg)

    Filling pressure (MPa)

    1.2

    1.2

    1.2

    Effective spray distance (m)

    ≥ 3.0

    ≥ 3.0

    ≥ 3.0

    Effective injection time (s)

    40 ≤ S≤ 210

    40 ≤ S≤ 210

    40 ≤ S≤ 210

    Fire extinguishing level

    4A,183B

    6A,233B

    6A,297B

    electrical insulation performance

    ≤ 36Kv

     

    Use temperature (℃)

    -20~ 55

     

             

     

    6. Cart-type carbon dioxide fire extinguisher

     

     

    Performance parameters

    Model specifications

    MTT/10

    MTT/20

    MTT/24

    MTT/30

    MTT/40

    Filling quantity of fire extinguishing agent (Kg)

    Filling coefficient

    ≤ 0.74

    Effective spray distance (m)

    ≥ 6

    Effective injection time (s)

    ≥ 20

    Fire extinguishing level

    55B,E

    70B,E

    89B,E

    89B,E

    113B,E

    Use temperature (℃)

    -10~ 55

     

     

    7. Simple water-based fire extinguisher

    Model specifications

    Fire extinguishing agent filling quantity

    ml

    Filling pressure

    MPa

    effective injection time

    s

    Effective spray distance

    m

    Fire extinguishing level

    Use temperature (℃)

    MSWJ580

    5800-29

    1.2

    ≥ 5

    ≥ 2

    0.5A, 8B, E, 5F

    5~ 55

    MSWJ950

    9500-47.5

    1.2

    ≥ 5

    ≥ 2

    0.5A, 21B, E, 5F

1. model preparation:


Classification

Code of fire extinguishing agent

Meaning of fire extinguishing agent code

Specific extinguishing agent characteristic code

Meaning of feature code

Water-based fire extinguisher

S

Clear water or water with additives, but does not have foaming multiple and 25% liquid separation time requirements

AR (does not have this performance do not write)

Ability to extinguish water soluble liquid fuel fires

P

Foam fire extinguishing agent with foaming multiple and 25% liquid separation time requirements

AR (does not have this performance do not write)

Ability to extinguish water soluble liquid fuel fires

Dry powder fire extinguisher

F

Dry powder extinguishing agent. Including BC type and ABC type

ABC(BC dry powder extinguishing agent does not write)

Ability to extinguish Class A fires

Carbon dioxide fire extinguisher

T

carbon dioxide extinguishing agent

-

 

Clean gas fire extinguisher

J

clean gas extinguishing agent

-

 

 

3. Executive Standard: GB4351.1-2005 Portable Fire Extinguishers Part 1: Performance and Structural Requirements
GB4351.2-2005 Portable Fire Extinguishers-Part 2: Requirements for portable carbon dioxide seamless steel cylinders

 

4. technical parameters:

 

 

 

1. Portable dry powder fire extinguisher

 

 

Performance parameters

Model specifications

MFZ/ABC1

MFZ/ABC2

MFZ/ABC3

MFZ/ABC4

MFZ/ABC5

MFZ/ABC6

MFZ/ABC8

Filling quantity of fire extinguishing agent (Kg)

1±0.05

2±0.06

3±0.09

4±0.08

5±0.1

6±0.12

8±0.16

Filling pressure (MPa)

1.2

1.2

1.2

1.2

1.2

1.2

1.2

Effective spray distance (m)

≥ 3.0

≥ 3.0

≥ 3.5

≥ 3.5

≥ 3.5

≥ 4.0

≥ 4.5

Effective injection time (s)

≥ 8

≥ 8

≥ 13

≥ 13

≥ 13

≥ 13

≥ 15

Fire extinguishing level

1A,21B

1A,21B

2A,34B

2A,55B

3A,89B

3A,89B

4A,144B

Use temperature (℃)

-20~ 55

 

2. Portable water-based fire extinguisher

 

 

Performance parameters

Model specifications

MFA/2

MFA/3

MFA/6

MFA/9

MSWZ/2

MSWZ/3

MFA/6

MSWZ/9

Filling quantity of fire extinguishing agent (Kg)

Filling pressure (MPa)

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

Effective spray distance (m)

≥ 3.0

≥ 3.0

≥ 3.5

≥ 4.0

≥ 3.0

≥ 3.0

≥ 3.5

≥ 4.0

Effective injection time (s)

≥ 15

≥ 15

≥ 30

≥ 40

≥ 15

≥ 15

≥ 30

≥ 40

Fire extinguishing level

1A,55B,E

1A,55B,E

2A,89B,E

3A,113B,E

1A,55B,E

1A,55B,E

2A,89B,E

3A,113B,E

electrical insulation performance

≤ 36Kv

Use temperature (℃)

-20~ 55

5~ 55

 

3. Portable carbon dioxide fire extinguisher

 

 

Performance parameters

Model specifications

MT/2

MT/3

MT/5

MT/7

Filling quantity of fire extinguishing agent (Kg)

Filling coefficient

≤ 0.6

≤ 0.6

≤ 0.6

≤ 0.6

Effective spray distance (m)

≥ 2.0

≥ 2.0

≥ 2.5

≥ 2.5

Effective injection time (s)

≥ 8

≥ 8

≥ 8

≥ 9

Fire extinguishing level

21B,C,E

21B,C,E

34B,C,E

55B,C,E

Use temperature (℃)

-10~ 55

 

4. Wheeled dry powder fire extinguisher

 

 

Performance parameters

Model specifications

MFTZ/ABC20

MFTZ/ABC25

MFTZ/ABC35

MFZ/ABC50

MFZ/ABC70

Filling quantity of fire extinguishing agent (Kg)

20±0.4

25±0.5

35±0.7

50±1.0

70±1.4

Filling pressure (MPa)

1.2

1.2

1.2

1.2

1.2

Effective spray distance (m)

≥ 6.0

≥ 6.0

≥ 6.0

≥ 6.0

≥ 6.0

Effective injection time (s)

≥ 30

≥ 30

≥ 30

≥ 30

≥ 30

Fire extinguishing level

6A,144B,C ,E

6A,183B,C ,E

10A,233B,C ,E

15A,297B,C ,E

15A,297B,C ,E

Use temperature (℃)

-20~ 55

 

5. Wheeled water-based fire extinguisher

 

 

Performance parameters

Model specifications

MFA/25

MFA/45

MFA/65

Filling quantity of fire extinguishing agent (Kg)

Filling pressure (MPa)

1.2

1.2

1.2

Effective spray distance (m)

≥ 3.0

≥ 3.0

≥ 3.0

Effective injection time (s)

40 ≤ S≤ 210

40 ≤ S≤ 210

40 ≤ S≤ 210

Fire extinguishing level

4A,183B

6A,233B

6A,297B

electrical insulation performance

≤ 36Kv

 

Use temperature (℃)

-20~ 55

 

         

 

6. Cart-type carbon dioxide fire extinguisher

 

 

Performance parameters

Model specifications

MTT/10

MTT/20

MTT/24

MTT/30

MTT/40

Filling quantity of fire extinguishing agent (Kg)

Filling coefficient

≤ 0.74

Effective spray distance (m)

≥ 6

Effective injection time (s)

≥ 20

Fire extinguishing level

55B,E

70B,E

89B,E

89B,E

113B,E

Use temperature (℃)

-10~ 55

 

 

7. Simple water-based fire extinguisher

Model specifications

Fire extinguishing agent filling quantity

ml

Filling pressure

MPa

effective injection time

s

Effective spray distance

m

Fire extinguishing level

Use temperature (℃)

MSWJ580

5800-29

1.2

≥ 5

≥ 2

0.5A, 8B, E, 5F

5~ 55

MSWJ950

9500-47.5

1.2

≥ 5

≥ 2

0.5A, 21B, E, 5F

MFTZ-ABC20.webp