Product classification


undefined
+
  • undefined

Click image to enlarge

Suction pipe

KG100

Retail price

Market price


Weight

kg

Quantity
-
+

Stock

隐藏域元素占位

Classification:

Key words:

Threaded interface

  • Product Description
    • Commodity name: Suction pipe
    • Commodity ID: KG100

    1. model preparation:

     

    Table 1

    Interface type

    Specifications

    Applicable media

    Inner buckle

    Name

    Code

    Nominal diameter/mm

    Nominal pressure/MPa

    Hindra interface

    KD

    25、40、50、65、80、100、125、135、150

    1.6、2.5

    Water, foam mixture

    KDN

    Pipe tooth interface

    KY

    SMOOTHING

    KM

    Internal thread fixing interface

    KN

    External thread fixing interface

    KWS

    KWA

    Reducing interface

    KJ

    Both ends of the diameter can be combined in the diameter series

    Card

    Hindra interface

    KDK

    40、50、65、80

    SMOOTHING

    KMK

    Tube tooth female interface

    KYK

    Pipe tooth male interface

    KYKA

    Reducing interface

    KJK

    Both ends of the diameter can be combined in the diameter series

    Threaded

    Suction pipe interface

    KG

    90、100、125、150

    1.0、1.6

    Water

    SMOOTHING

    KA

    same type interface

    KT

    Note: KD indicates the hose interface of external hoop type connection, KDN indicates the hose interface of internal expansion type connection, KWS indicates the external thread fixing interface for overground fire-fighting, and KWA indicates the external thread fixing interface for overground fire-fighting.

     

    Example: KD65 represents an outer hoop hose interface with a nominal pressure of 1.6MPa and a nominal diameter of 65mm.
    KDK80Z represents a cassette water belt interface with a nominal pressure of 2.5MPa and a nominal diameter of 80mm.
    KG100 indicates that the nominal pressure is 1.0MPa and the nominal diameter is 100mm.


    2. implementation standards:

    GB12514.1-2005-Fire Interface-Part 1: General Technical Conditions for Fire Interface
    GB12514.2-2006 Fire Interface-Part 2: Type and Basic Parameters of Internal Buckle Fire Interface
    GB12514.3-2006-Fire Interface-Part 3: Type and Basic Parameters of Card-type Fire Interface
    GB12514.4-2006 Fire Interface Part 4: Type and Basic Parameters of Threaded Fire Interface

     

    3. technical parameters:


     

    Product Name

    Model specifications

    Nominal passage/mm

    Sealing performance/MPa

    Applicable media

    Inner buckle hose interface

    KD50

    50

    1.6

    Water, foam mixture

    KD65

    65

    KD80

    80

    KD100

    100

    KD125

    125

    KD135

    135

    KD150

    150

    KD65Z

    65

    2.5

    KD80Z

    80

    Buckle-type pipe tooth interface

    KY50

    50

    1.6

    KY65

    65

    KY80

    80

    KY100

    100

    KY125

    125

    KY135

    135

    KY150

    150

    Buckle-type closure

    KM80

    80

    1.6

    KM100

    100

    KM125

    125

    KM135

    135

    KM150

    150

    Internal thread fixing interface

    KN50

    50

    1.6

    KN60

    65

    Internal thread fixing interface

    KWS65

    65

    1.6

    KWS80

    80

    KWA65

    65

    KWA80

    80

    Internal buckle reducing interface

    KJ65/80

    65/80

    1.6

    cassette hose interface

    KDK65Z

    65

    2.5

    KDK80Z

    80

    Cam-type pipe male interface

    KYK65Z

    65

    2.5

    2.5

    KYK80Z

    80

    Female interface of clip-type pipe tooth

    KYKA65Z

    65

    2.5

    KYKA80Z

    80

    Card-type reducing interface

    KJK65/80AZ

    65/80

    2.5

    KJK65A/80Z

    Special-shaped interface

    KY65/KYKA65Z

    65

    2.5

    KY65/KYKA80Z

    65/80

    KY65/KYK65Z

    65

    KY80/KYK80Z

    80

     

    4. applicable places: used in fire brigades, various fire engines, petrochemical enterprises, fire boats, oil drilling platforms and other places.

1. model preparation:

 

Table 1

Interface type

Specifications

Applicable media

Inner buckle

Name

Code

Nominal diameter/mm

Nominal pressure/MPa

Hindra interface

KD

25、40、50、65、80、100、125、135、150

1.6、2.5

Water, foam mixture

KDN

Pipe tooth interface

KY

SMOOTHING

KM

Internal thread fixing interface

KN

External thread fixing interface

KWS

KWA

Reducing interface

KJ

Both ends of the diameter can be combined in the diameter series

Card

Hindra interface

KDK

40、50、65、80

SMOOTHING

KMK

Tube tooth female interface

KYK

Pipe tooth male interface

KYKA

Reducing interface

KJK

Both ends of the diameter can be combined in the diameter series

Threaded

Suction pipe interface

KG

90、100、125、150

1.0、1.6

Water

SMOOTHING

KA

same type interface

KT

Note: KD indicates the hose interface of external hoop type connection, KDN indicates the hose interface of internal expansion type connection, KWS indicates the external thread fixing interface for overground fire-fighting, and KWA indicates the external thread fixing interface for overground fire-fighting.

 

Example: KD65 represents an outer hoop hose interface with a nominal pressure of 1.6MPa and a nominal diameter of 65mm.
KDK80Z represents a cassette water belt interface with a nominal pressure of 2.5MPa and a nominal diameter of 80mm.
KG100 indicates that the nominal pressure is 1.0MPa and the nominal diameter is 100mm.


2. implementation standards:

GB12514.1-2005-Fire Interface-Part 1: General Technical Conditions for Fire Interface
GB12514.2-2006 Fire Interface-Part 2: Type and Basic Parameters of Internal Buckle Fire Interface
GB12514.3-2006-Fire Interface-Part 3: Type and Basic Parameters of Card-type Fire Interface
GB12514.4-2006 Fire Interface Part 4: Type and Basic Parameters of Threaded Fire Interface

 

3. technical parameters:


 

Product Name

Model specifications

Nominal passage/mm

Sealing performance/MPa

Applicable media

Inner buckle hose interface

KD50

50

1.6

Water, foam mixture

KD65

65

KD80

80

KD100

100

KD125

125

KD135

135

KD150

150

KD65Z

65

2.5

KD80Z

80

Buckle-type pipe tooth interface

KY50

50

1.6

KY65

65

KY80

80

KY100

100

KY125

125

KY135

135

KY150

150

Buckle-type closure

KM80

80

1.6

KM100

100

KM125

125

KM135

135

KM150

150

Internal thread fixing interface

KN50

50

1.6

KN60

65

Internal thread fixing interface

KWS65

65

1.6

KWS80

80

KWA65

65

KWA80

80

Internal buckle reducing interface

KJ65/80

65/80

1.6

cassette hose interface

KDK65Z

65

2.5

KDK80Z

80

Cam-type pipe male interface

KYK65Z

65

2.5

2.5

KYK80Z

80

Female interface of clip-type pipe tooth

KYKA65Z

65

2.5

KYKA80Z

80

Card-type reducing interface

KJK65/80AZ

65/80

2.5

KJK65A/80Z

Special-shaped interface

KY65/KYKA65Z

65

2.5

KY65/KYKA80Z

65/80

KY65/KYK65Z

65

KY80/KYK80Z

80

 

4. applicable places: used in fire brigades, various fire engines, petrochemical enterprises, fire boats, oil drilling platforms and other places.